| Date: 6/12/2008 | Time: 09:30 AM | Report ID: Sample report 6-2008 |
| Property: 19268 E. 22nd Terrace Independence, MO 64057 |
Customer: David Prospect 816-235-7890 |
Real Estate Professional: Bob Firstgold Firstgold Realty 816-455-9908 |
Client Is Present: Yes | Age Of Home: 6 | Weather: Clear |
Temperature: 72 | Rain in last 3 days: Yes | Soil Condition: Wet |
House Faces: South | Distribution of Seller/Owner's Disclosure Notice.: The inspector was provided with a copy of the "Seller/Owner Disclosure Notice" | Radon Test: No |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Evaluate, Repair or Replace (ER) = The item, component or unit is not functioning as intended or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement
NOTE: Inspections performed under the NAHI Standards exclude any item(s) concealed or not readily accessible to the Inspector. The Inspector is NOT required to move furniture, personal, or stored items; lift floor coverings: move attached wall, ceiling coverings, or panels; or perform any test(s) or procedure(s) which could damage or destroy the item(s) being evaluated.
The inspection and report are OPINIONS only, based upon visual observation of the existing conditions of the inspected property at time of inspection. THE REPORT IS NOT INTENDED TO BE, OR TO BE CONSTRUED AS A GUARANTEE, WARRANTY, OR ANY FORM OF INSURANCE. The Inspector will NOT be responsible for any repair or replacement with regard to the property or the condition thereof
NOTE: Attachments are included at the end of the report for your information. They should be read with the inspection report.

816.665.5346
www.m3inspect.com
david@m3inspect.com
Customer
David Prospect
Address
19268 E. 22nd Terrace
Independence, MO 64057
The Summary is included as a convenience, not as a report substitute. It is essential that all portions of the home inspection report be read and carefully considered
.The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation.
It is recommended that any deficiencies and the components/systems related to these deficiencies noted in the report be evaluated/inspected and repaired as needed by a licensed contractor/profession prior to closing. It is also recommended the entire system of noted deficiencies be evaluated prior to closing by the licensed contractor/professional for additional concerns that maybe outside our area of expertise or the scope of this inspection.
The entire Inspection Report, The NAHI Standards of Practice, and the M3 Real Estate Inspection Agreement must be carefully read to fully assess the findings of the inspection.
This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home.
Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.
| 1. KITCHEN & LAUNDRY | ||||||
|
| 2. BATHROOMS | ||||||||||||
|
| 4. PLUMBING | ||||||
|
| 5. COOLING SYSTEMS | ||||||
|
| 6. HEATING SYSTEMS | ||||||
|
| 7. ELECTRICAL SYSTEMS | ||||||
|
| 10. ROOFING | ||||||
|
| 11. GROUNDS | ||||||||||||
|
| Styles & Materials RANGE/OVEN: ELECTRIC ARE OUTLETS AT SINK GFCI PROTECTED: YES WASHER POWER SOURSE: ELECTRIC DRYER POWER SOURCE: ELECTRIC DRYER VENT:
PRESENT |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
| Styles & Materials BATH with TUB and/or SHOWER: 2ND FLOOR HALL LOWER LEVEL BATH with WHIRLPOOL and SHOWER: MASTER 1/2 BATH: LOWER LEVEL NUMNBER of BATH ROOMS:
3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
| Styles & Materials WINDOW TYPE: THERMAL PANE VINYL INTERIOR WALLS: DRYWALL / PLASTER INTERIOR CEILINGS: DRYWALL / PLASTER FIREPLACE TYPE: METAL PREFAB GAS LIGHTER FIREPLACE (S):
ONE |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
![]() |
| Styles & Materials WATER SOURCE: PUBLIC WASTE DISPOSAL: PUBLIC WATER SUPPLY LINES: COPPER DRAIN / WASTE / VENT: PLASTIC WATER HEATER: GAS ESTIMATED SIZE: 50 GAL ESTIMATED AGE:
5-10 YRS |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
Recommend a licensed and competent plumber of your choice assess and make needed repairs prior to the end of your inspection period.
![]() |
| Styles & Materials COOLING EQUIPMENT TYPE: CENTRAL A/C FUEL SOURCE: ELECTRIC SPLIT SYSTEM NUMBER OF A/C UNITS: ONE ESTIMATED SIZE: 3-4 TON ESTIMATED AGE:
5-10 YRS |
||||||||||||||||||||||||||||||||||||||||||||||||
| Styles & Materials HEAT TYPE: FORCED AIR FUEL: GAS DISTRIBUTION: DUCTS NUMBER OF FURNACES (excluding wood): ONE ESTIMATED SIZE: 90000-100000 BTU ESTIMATED AGE:
5-10 YRS |
||||||||||||||||||||||||||||||||||||
| Styles & Materials SERVICE ENTRANCE: UNDERGROUND SIZE OF SERVICE: 200 AMP SUB PANEL: NO MAIN DISCONNECT: BREAKERS MAIN CABLE: ALUMINUM BRANCH WIRE 120 VOLT: COPPER BRANCH WIRE 240 VOLT: COPPER MAIN GROUNDING: WATER PIPE WIRING METHODS:
3-PRONG OUTLETS ROMEX |
||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
| Styles & Materials FOUNDATION TYPE: BASEMENT FOUNDATION WALLS: CONCRETE FOUNDATION FLOOR: CONCRETE SUB FLOOR SYSTEM: 2 X 10 WOOD JOISTS VISIBLE SUPPORT COLUMNS:
NOT VISIBLE |
||||||||||||||||||||||||||||||||||||||||||||||||
We did not observe any conditions that in the inspectors opinion are significant defects at the time of the inspection. However there is always a possibility that there are structural defects, environmental issues or pest activity or adverse conditions present at hidden or concealed areas. We know nothing of the presence or absence of defects at these areas. If this is a concern to the buyer, we recommend that they have further evaluation by a specialist prior to the end of your inspection period or close. The inspection company can not be held liable for Hidden or Concealed damage
![]() |
![]() | ![]() |
![]() | ![]() |
| Styles & Materials GARAGE STYLE: ATTACHED GARAGE DOOR MATERIAL: HARDBOARD GARAGE TYPE: THREE AUTOMATIC ROOF COVERINGS: SAME AS HOUSE GARAGE ROOF / CEILING: RAFTERS / JOISTS /TRUSSES ATTIC DESCRIPTION: MULTIPLE ATTIC INSPECTED BY: VIEWED FROM ACCESS NO SECURE / SOLID WALKWAY ROOF / CEILING FRAME: RAFTERS& JOISTS INSULATION: LOOSE BATT INSULATION DEPTH:
8 to 14 INCHES +/- |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
![]() |
![]() |
![]() | ![]() |
| Styles & Materials ROOF TYPE: GABLE HIP COMBINATION ROOF COVERING& LAYERS: COMPOSITION SHINGLES 1 LAYER ROOF SLOPE: STEEP ROOF VENTILATION: SOFFIT ROOF VENTS ROOF INSPECTED BY: WALKED ON ROOF LADDER GROUND BINOCULARS (inspection is limited) GUTTER TYPE: FULL METAL SKY LIGHT (S):
NONE |
||||||||||||||||||||||||||||||||||||||||||||||||
![]() | ![]() |
![]() | ![]() |
![]() | ![]() |
![]() |
| Styles & Materials DRIVEWAY TYPE: CONCRETE SIDEWALKS: N/A PORCH / STOOP / STEPS: CONCRETE RETAINING WALL: N/A PATIO TYPE: CONCRETE DECK / BALCONY:
WOOD |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() | ![]() |
![]() |
![]() |
| Styles & Materials EXTERIOR WALLS: WOOD FRAME WALL COVERING: FIBROUS HARBOARD STONE VENEER EXTERIOR TRIM: FIBORUS HARDBOARD CHIMNEY TYPE:
FIBOROUS CHASE |
||||||||||||||||||||||||||||||||||||
![]() |
There were no weep holes present at the bottom of the masonry veneer walls. Although the local building codes don't exempt them NOR require builders to install them, our building code requires they be present. If water should get behind OR through the brick which is a porous material, weep holes can provide the moisture a way out of the wall cavity".
"Without this exit point, water can be trapped inside the wall cavity forming mold, mildew or causing hidden moisture damage, etc. This company did not perform intrusive testing for these conditions, and have no ability to verify the absence or presence of defective conditions inside wall cavities. We recommend having further intrusive moisture testing, damage assessment and mold testing of all wall cavities performed prior to leaving your inspection contingency period".
"We also recommend having a licensed and competent brick mason retrofit all exterior walls with proper weep holes per a licensed architects design".
Gaps and overdriven fasteners should be caulked to eliminate possible moisture penetration, found on all sides of the home.
![]() | ![]() |
![]() |
![]() |
![]() |
|
INVOICE |
| M3 Real Estate Inspection, LLC
816.665.5346 www.m3inspect.com david@m3inspect.com Inspected By: David Moriconi, CRI |
Inspection Date: 6/12/2008
Report ID: Sample report 6-2008 |
| Customer Info: | Inspection Property: |
| David Prospect
2269 SH 43 North Jefferson TX 75657 816-235-7890 Customer's Real Estate Professional: Bob Firstgold Firstgold Realty |
19268 E. 22nd Terrace Independence, MO 64057 |
Inspection Fee:
| ||||||||||||
Tax $0.00 | ||||||||||||
| Total Price $380.00 |
Payment Method:Check
Payment Status:Paid At Time Of Inspection
Note:
![]() M3 Real Estate Inspection, LLC
816.665.5346 |