Property Address:
586 Mountain Fancy Drive
Big Lake NC 28715
Russell Buchanan
122 Lyman Street
Asheville, NC 28801
828-254-2030
Date: 5/17/2017 | Time: 1:00 PM | Report ID: |
Property: 586 Mountain Fancy Drive Big Lake NC 28715 |
Customer: Sample Buyer |
Real Estate Professional: Nath Dau-Schmidt DauSchmidt Realty |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
In Attendance: Customer and their agent | Type of building: Single Family (2 story) | Approximate age of building: Over 10 Years |
Temperature: Over 65 (F) = 18 (C) | Weather: Clear | Ground/Soil surface condition: Dry |
Rain in last 3 days: No | Radon Test: Yes | Water Test: No |
The inspector is not required to: Walk on any roof surface, predict the service life expectancy, inspect underground downspout diverter drainage pipes, remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces, move insulation, inspect antennae, satellite dishes, lightning arresters, de-icing equipment, or similar attachments. Walk on any roof areas that appear, in the opinion of the inspector to be unsafe, and or cause damage. Perform a water test, warrant or certify the roof. Confirm proper fastening or installation of any roof material.
Roof Covering:
Asphalt/Fiberglass |
Viewed roof covering from:
Ground |
Chimney (exterior):
Masonry Stucco |
1.0 |
Roof Coverings
Comments: Inspected |
1.1 |
Flashings
Comments: Inspected |
1.2 |
Skylights, Chimneys and Roof Penetrations
Comments: Inspected |
1.3 |
Roof Drainage Systems
Comments: Repair or Replace |
Drain line has sunken or pulled loose from downspout. This area needs repair.
1.3 Item 1(Picture)
|
The inspector is not required to: Inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting, Inspect items, including window and door flashings, which are not visible or readily accessible from the ground, Inspect geological, geotechnical, hydrological and/or soil conditions, Inspect recreational facilities, playground equipment. Inspect seawalls, break-walls and docks, Inspect erosion control and earth stabilization measures, Inspect for safety type glass, Inspect underground utilities, Inspect underground items, Inspect wells or springs, Inspect solar, wind or geothermal systems, Inspect swimming pools or spas, Inspect wastewater treatment systems septic systems or cesspools, Inspect irrigation or sprinkler systems, Inspect drain fields or drywells, Determine the integrity of multi-pane window glazing or the thermal window seals.
Siding Style:
Rock and Mortar Cement stucco |
Siding Material:
Stone Masonry |
Exterior Entry Doors:
Wood |
Appurtenance:
Balcony Sidewalk |
Driveway:
Asphalt |
2.0 |
Wall Cladding Flashing and Trim
Comments: Repair or Replace |
(1) The stucco siding, trim and fascia are in need of cleaning and repainting throughout. Gutters will need to be temporarily removed to paint and then re-install. | |
(2) The gable wood work on at least two locations shows signs of some damage from carpenter bees etc. and need repair and prep and paint.
2.0 Item 1(Picture)
|
|
(3) Some repair areas noticed
2.0 Item 2(Picture)
|
2.1 |
Doors (Exterior)
Comments: Repair or Replace |
(1) Weather stripping on a few exterior doors are loose, missing or damaged in areas..
2.1 Item 1(Picture) balcony from kitchen
2.1 Item 2(Picture) garage
|
|
(2) Stain used to protect main doors has faded or failed, and need prep and stain again.
2.1 Item 3(Picture)
|
2.2 |
Windows
Comments: Repair or Replace |
Window trim is damaged at the rear of home over the extra room (seen from ground level).
2.2 Item 1(Picture)
|
2.3 |
Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings
Comments: Repair or Replace |
(1) The master suite balcony floor is deteriorated. Water has came in along front or outer band where tile or trim failed to cover seam when installed. Tile is cracked in
an area. Guard rail and tile will need to be replaced. Guard rail can be re used but tile likely cannot. Subfloor will need to be replaced along front length of balcony
and side nearest door and install tile and seal.
2.3 Item 1(Picture)
2.3 Item 2(Picture)
2.3 Item 3(Picture)
|
|
(2) Loose stone at steps of home at entry.
2.3 Item 4(Picture)
|
|
(3) Balcony off Living room will need railings cleaned and painted. Some areas of supports for railing appear weathered and light deterioration may exist. | |
(4) Decorative railing at parking lot is rusting and needs rust inhibitor, sanding and paint. Also on the roof and due to the slope a boom vehicle may be needed to
access and properly prep and paint.
2.3 Item 5(Picture)
|
2.4 |
Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building)
Comments: Repair or Replace |
(1) Driveway does not drain water and an attempt to correct with trench drains is not par with the expectations of this home and does not appear to work. Uneven or sag
in areas. A proper repair is to remove pavement, slope correctly and apply new pavement.
2.4 Item 1(Picture)
2.4 Item 2(Picture)
|
|
(2) Reattaining wall has at least one loose stone and some areas need grout again and sealant applied.
2.4 Item 3(Picture)
|
2.5 |
Eaves, Soffits and Fascias
Comments: Inspected |
(1) See Wall Cladding comments involving the need to prep and paint to protect. | |
(2) Hornets nest "active" and is quickly forming above balcony
2.5 Item 1(Picture)
|
2.6 |
Other
Comments: Not Inspected |
The decorative pond out front is not working. This could be because the pond leaks or is not operable?
2.6 Item 1(Picture)
|
The inspector is not required to: Enter any crawlspaces that are not readily accessible or where entry could cause damage or pose a hazard to the inspector, Move stored items or debris, Operate sump pumps with inaccessible floats, Identify size, spacing, span, location or determine adequacy of foundation bolting, bracing, joists, joist spans or support systems, Provide any engineering or architectural service, Report on the adequacy of any structural system or component.
Foundation:
Masonry block Rock Poured concrete |
Method used to observe Crawlspace:
No crawlspace |
Floor Structure:
Wood joists Slab Not visible |
Wall Structure:
Wood Masonry |
Columns or Piers:
Masonry block Steel lally columns Supporting walls |
Ceiling Structure:
Not visible |
Roof Structure:
Engineered wood trusses Stick-built |
Roof-Type:
Gable Hip |
Method used to observe attic:
Walked Inaccessible |
Attic info:
Attic access Pull Down stairs Storage Light in attic |
3.0 |
Foundations, Basement and Crawlspace (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.)
Comments: Inspected |
3.1 |
Walls (Structural)
Comments: Repair or Replace |
Rock wall has settled or continues to settle and repair signs indicate it has settled previously and has settled more or again. Repairs
are needed to wall and cement chinking. See roof section at Gutters and downspouts for more repair recommendations.
3.1 Item 1(Picture)
|
3.2 |
Columns or Piers
Comments: Inspected |
3.3 |
Floors (Structural)
Comments: Inspected |
3.4 |
Ceilings (Structural)
Comments: Inspected |
3.5 |
Roof Structure and Attic
Comments: Inspected |
Insects dead from entering around window area in attic (FYI).
3.5 Item 1(Picture)
|
The inspector is not required to: Inspect or evaluate interiors of flues or chimneys, fire chambers, heat exchangers, humidifiers, dehumidifiers, electronic air filters, solar heating systems, solar heating systems or fuel tanks. Inspect underground fuel tanks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. Light or ignite pilot flames. Activate heating, heat pump systems, or other heating systems when ambient temperatures or when other circumstances are not conducive to safe operation or may damage the equipment. Override electronic thermostats. Evaluate fuel quality. Verify thermostat calibration, heat anticipation or automatic setbacks, timers, programs or clocks. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. Inspect window units, through-wall units, or electronic air filters. Operate equipment or systems if exterior temperature is below 60 degrees Fahrenheit or when other circumstances are not conducive to safe operation or may damage the equipment. Inspect or determine thermostat calibration, heat anticipation or automatic setbacks or clocks. Examine electrical current, coolant fluids or gasses, or coolant leakage. Inspect the flue or vent system. Inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels. Determine the need for a chimney sweep. Operate gas fireplace inserts. Light pilot flames. Determine the appropriateness of such installation. Inspect automatic fuel feed devices. Inspect combustion and/or make-up air devices. Inspect heat distribution assists whether gravity controlled or fan assisted. Ignite or extinguish fires. Determine draft characteristics. Move fireplace inserts, stoves, or firebox contents. Determine adequacy of draft, perform a smoke test or dismantle or remove any component. Perform an NFPA inspection. Perform a Phase 1 fireplace and chimney inspection.
Heat Type:
Furnace |
Energy Source:
Gas |
Number of Heat Systems (excluding wood):
Three |
Ductwork:
Insulated |
Filter Type:
Disposable |
Types of Fireplaces:
Vented gas logs |
Operable Fireplaces:
Three |
Number of Woodstoves:
None |
Cooling Equipment Type:
Air conditioner unit |
Cooling Equipment Energy Source:
Electricity |
4.0 |
Heating and Cooling Equipment
Comments: Repair or Replace |
Air handler was leaking condensation into the drain pan. The drain pan was full and eventually the safety switch did cut off unit.
However it still leaked which could mean that the pan itself may leak at a seam? Note: The listing agent called a HVAC person who did
replace the filter that was clogged and troubleshooted the system. I did not see if he removed the standing water. Not doing so can
cause more to leak onto the ceiling below. The ceiling below was dripping water and has already stained. I did not inspect for mold and
it could develop. Repairs if air handler was repaired will likely be prime seal ceiling and re paint.
4.0 Item 1(Picture)
4.0 Item 2(Picture)
4.0 Item 3(Picture)
|
4.1 |
Normal Operating Controls
Comments: Inspected |
4.2 |
Automatic Safety Controls
Comments: Inspected |
4.3 |
Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments: Inspected |
4.4 |
Presence of Installed Heat Source in Each Room
Comments: Inspected |
4.5 |
Chimneys, Flues and Vents (for fireplaces, gas water heaters or heat systems)
Comments: Inspected |
4.6 |
Solid Fuel Heating Devices (Fireplaces, Woodstove)
Comments: Not Present |
4.7 |
Gas/LP Firelogs and Fireplaces
Comments: Repair or Replace |
The remote for Formal Living room fireplace was not found and I could not turn on fireplace? |
4.8 |
Presence of Installed Cooling Source in Each Room
Comments: Inspected |
The inspector is not required to: Light or ignite pilot flames. Determine the size, temperature, age, life expectancy or adequacy of the water heater. Inspect interiors of flues or chimneys, water softening or filtering systems, well pumps or tanks, safety or shut-of valves, floor drains, lawn sprinkler systems or fire sprinkler systems. Determine the exact flow rate, volume, pressure, temperature, or adequacy of the water supply. Determine the water quality or potability or the reliability of the water supply or source. Open sealed plumbing access panels. Inspect clothes washing machines or their connections. Operate any main, branch or fixture valve. Test shower pans, tub and shower surrounds or enclosures for leakage. Evaluate the compliance with local or state conservation or energy standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping. Determine the effectiveness of anti-siphon, back-flow prevention or drain-stop devices. Determine whether there are sufficient clean-outs for effective cleaning of drains. Evaluate gas, liquid propane or oil storage tanks. Inspect any private sewage waste disposal system or component of. Inspect water treatment systems or water filters. Inspect water storage tanks, pressure pumps or bladder tanks. Evaluate time to obtain hot water at fixtures, or perform testing of any kind to water heater elements. Evaluate or determine the adequacy of combustion air. Test, operate, open or close safety controls, manual stop valves and/or temperature or pressure relief valves. Examine ancillary systems or components, such as, but not limited to, those relating to solar water heating, hot water circulation.
Water Source:
Public |
Water Filters:
None |
Plumbing Water Supply (into home):
Not visible |
Plumbing Water Distribution (inside home):
PEX Not visible |
Washer Drain Size:
2" Diameter |
Plumbing Waste:
PVC |
Water Heater Power Source:
Gas (quick recovery) |
Water Heater Location:
Basement |
5.0 |
Plumbing Drain, Waste and Vent Systems
Comments: Repair or Replace |
(1) Both sinks in shared bathroom upstairs drains slow.
5.0 Item 1(Picture)
5.0 Item 2(Picture)
|
|
(2) The diverter on tub spout does not divert all water from tub to shower enough to affect the flow. |
5.1 |
Plumbing Water Supply, Distribution System and Fixtures
Comments: Repair or Replace |
(1) Shower fixture leaked in a few areas where seals may be old. Recommend repair or replace as necessary.
5.1 Item 1(Video)
|
|
(2) Control knobs for guest bath sink upstairs (light blue room) appear to be installed opposite to normal direction to turn water off and on.
Volume or pressure here is somewhat low compared to the other plumbing locations in the home.
5.1 Item 2(Video)
|
|
(3) Protective cover for fixture has sagged or loosened to where water can get in behind wall at light blue guest bedroom upstairs and at
master shower,
5.1 Item 3(Picture)
5.1 Item 4(Picture)
|
5.2 |
Hot Water Systems, Controls, Chimneys, Flues and Vents
Comments: Repair or Replace |
Water connection to water heater leaks or has corroded and may have temporarily stopped leaking due to corrosion? A plumber
should repair or replace as needed.
5.2 Item 1(Picture)
|
5.3 |
Main Water Shut-off Device (Describe location)
Comments: Repair or Replace |
Main water has leaked or leaking at connection. Drip stains seen on replacement filters for HVAC being stored below. This is a high
pressure area and needs connection fittings replaced. Line could rupture or become worse. A plumber should replace.
5.3 Item 1(Picture)
|
5.4 |
Fuel Storage and Distribution Systems (Interior fuel storage, piping, venting, supports, leaks)
Comments: Inspected |
5.5 |
Main Fuel Shut-off (Describe Location)
Comments: Inspected |
At gas meter outside is the main shut-off location for all gas into home. |
5.6 |
Sump Pump
Comments: Not Present |
The inspector is not required to: Insert any tool, probe or device into the main panel, sub-panels, downstream panel, or electrical fixtures. Operate electrical systems that are shut down. Remove panel covers or dead front covers if not readily accessible. Operate over current protection devices. Operate non-accessible smoke detectors. Measure or determine the amperage or voltage of the main service if not visibly labeled. Inspect the alarm system and components. Inspect the ancillary wiring or remote control devices. Activate any electrical systems or branch circuits which are not energized. Operate overload devices. Inspect low voltage systems, electrical de-icing tapes, swimming pool wiring or any time-controlled devices. Verify the continuity of the connected service ground. Inspect private or emergency electrical supply sources, including but not limited to generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility. Inspect spark or lightning arrestors. Conduct voltage drop calculations. Determine the accuracy of breaker labeling. Inspect exterior lighting.
Electrical Service Conductors:
Below ground Aluminum 220 volts |
Panel Capacity:
200 AMP |
Panel Type:
Circuit breakers GFCI Breakers |
Branch wire 15 and 20 AMP:
Copper |
Wiring Methods:
Romex Not Visible |
6.0 |
Service Entrance Conductors
Comments: Inspected |
6.1 |
Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels
Comments: Inspected |
6.2 |
Branch Circuit Conductors, Overcurrent Devices and Compatability of their Amperage and Voltage
Comments: Inspected |
6.3 |
Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments: Repair or Replace |
I was unable to see the light fixture work or come on in the upstairs Master? It could be that all bulbs are burned out or it may require
an electrician.
6.3 Item 1(Picture)
|
6.4 |
Polarity and Grounding of Receptacles within 6 feet of interior plumbing fixtures, all receptacles in garage, carport and exterior walls of inspected structure
Comments: Inspected |
6.5 |
Operation of GFCI (Ground Fault Circuit Interrupters)
Comments: Inspected |
6.6 |
Operation of AFCI (ARC Fault Circuit Interrupters)
Comments: Inspected |
6.7 |
Location of Main and Distribution Panels
Comments: Inspected |
6.8 |
Smoke Detectors
Comments: Inspected |
The smoke detector should be tested at common hallway to bedrooms upon moving in to home. |
6.9 |
Carbon Monoxide Detectors
Comments: Inspected |
Attic Insulation:
Blown Fiberglass |
Ventilation:
Ridge vents Soffit Vents |
Exhaust Fans:
Fan |
Dryer Power Source:
220 Electric |
Dryer Vent:
Flexible Metal |
Floor System Insulation:
Batts |
7.0 |
Insulation in Attic
Comments: Inspected |
7.1 |
Insulation Under Floor System
Comments: Inspected |
7.2 |
Vapor Retarders (in Crawlspace or basement)
Comments: Not Inspected |
Not visible, finished surfaces |
7.3 |
Ventilation of Attic and Foundation Areas
Comments: Inspected |
7.4 |
Venting Systems (Kitchens, Baths and Laundry)
Comments: Inspected |
7.5 |
Ventilation Fans and Thermostatic Controls in Attic
Comments: Not Present |
The inspector shall: Open and close a representative number of doors and windows. Inspect the walls, ceilings, steps, stairways, and railings. Inspect garage doors and garage door openers by operating first by remote (if available) and then by the installed automatic door control. And report as in need of repair any installed electronic sensors that are not operable or not installed at proper heights above the garage door. And report as in need of repair any door locks or side ropes that have not been removed or disabled when garage door opener is in use. And report as in need of repair any windows that are obviously fogged or display other evidence of broken seals.
The inspector is not required to: Inspect paint, wallpaper, window treatments or finish treatments. Inspect central vacuum systems. Inspect safety glazing. Inspect security systems or components. Evaluate the fastening of countertops, cabinets, sink tops and fixtures, or firewall compromises. Move furniture, stored items, or any coverings like carpets or rugs in order to inspect the concealed floor structure. Move drop ceiling tiles. Inspect or move any household appliances. Inspect or operate equipment housed in the garage except as otherwise noted. Verify or certify safe operation of any auto reverse or related safety function of a garage door. Operate or evaluate security bar release and opening mechanisms, whether interior or exterior, including compliance with local, state, or federal standards. Operate any system, appliance or component that requires the use of special keys, codes, combinations, or devices. Operate or evaluate self-cleaning oven cycles, tilt guards/latches or signal lights. Inspect microwave ovens or test leakage from microwave ovens. Operate or examine any sauna, steam-jenny, kiln, toaster, ice-maker, coffee-maker, can-opener, bread-warmer, blender, instant hot water dispenser, or other small, ancillary devices. Inspect elevators. Inspect remote controls. Inspect appliances. Inspect items not permanently installed. Examine or operate any above-ground, movable, freestanding, or otherwise non-permanently installed pool/spa, recreational equipment or self-contained equipment. Come into contact with any pool or spa water in order to determine the system structure or components. Determine the adequacy of spa jet water force or bubble effect. Determine the structural integrity or leakage of a pool or spa.
Ceiling Materials:
Gypsum Board |
Wall Material:
Gypsum Board |
Floor Covering(s):
Carpet Hardwood T&G Stone Tile |
Interior Doors:
Raised panel |
Window Types:
Thermal/Insulated Casement |
Cabinetry:
Wood Veneer |
Countertop:
Granite |
8.0 |
Ceilings
Comments: Repair or Replace |
Tape used to bed Gypsum board seams are loose, failed in a few areas of home including 4 corners of highest ceiling as well as Master bedroom upstairs. Work will
require painting all ceiling to match. Due to the height this will require a means to access the area, and can increase the cost to repair.
8.0 Item 1(Picture)
|
8.1 |
Walls
Comments: Repair or Replace |
Baseboard and trim missing from both sides of fireplace in Master bedroom.
8.1 Item 1(Picture)
8.1 Item 2(Picture)
|
8.2 |
Floors
Comments: Repair or Replace |
Tile floor in Master needs grout where missing and reseal.
8.2 Item 1(Picture)
8.2 Item 2(Picture)
|
8.3 |
Steps, Stairways, Balconies and Railings
Comments: Inspected |
8.4 |
Counters and Cabinets (representative number)
Comments: Inspected |
8.5 |
Doors (representative number)
Comments: Inspected |
8.6 |
Windows (representative number)
Comments: Repair or Replace |
(1) Double window cannot open fully due to the gutter being too low at shared bathroom upstairs.
8.6 Item 1(Picture)
|
|
(2) Window in light blue guest bedroom upstairs is showing odd signs between glass that looks like blisters? It does not appear cloudy. Replace if desired. |
Garage Door Type:
Three automatic |
Garage Door Material:
Wood |
9.0 |
Garage Ceilings
Comments: Inspected |
9.1 |
Garage Walls (including Firewall Separation)
Comments: Inspected |
9.2 |
Garage Floor
Comments: Inspected |
Typical settlement cracks |
9.3 |
Garage Door (s)
Comments: Repair or Replace |
All three garage doors are no longer protected by the stain or sealant and are starting to peel, fade and eventually deteriorate.
9.3 Item 1(Picture)
9.3 Item 2(Picture)
9.3 Item 3(Picture)
9.3 Item 4(Picture)
|
9.4 |
Occupant Door (from garage to inside of home)
Comments: Inspected |
9.5 |
Garage Door Operators (Report whether or not doors will reverse when met with resistance)
Comments: Repair or Replace |
Garage door 1st on left from outside will not close properly and requires holding button in. |
9.6 |
Garage window (s)
Comments: Inspected |
Dishwasher Brand:
KITCHEN AIDE |
10.0 |
Dishwasher
Comments: Repair or Replace |
It appears that the silverware tray is missing?
10.0 Item 1(Picture)
|
10.1 |
Ranges/Ovens/Cooktops
Comments: Inspected |
10.2 |
Range Hood (s)
Comments: Inspected |
10.3 |
Food Waste Disposer
Comments: Inspected |
Push button for operation wanted to remain in when using. |
11.0 |
360 degree photos
|
122 Lyman Street
Asheville, NC 28801
828-254-2030
Customer
Sample Buyer
Address
586 Mountain Fancy Drive
Big Lake NC 28715
1.3 | Roof Drainage Systems | |
Repair or Replace | ||
Drain line has sunken or pulled loose from downspout. This area needs repair.
1.3 Item 1(Picture)
|
2.0 | Wall Cladding Flashing and Trim | |
Repair or Replace | ||
(1) The stucco siding, trim and fascia are in need of cleaning and repainting throughout. Gutters will need to be temporarily removed to paint and then re-install.
|
||
(2) The gable wood work on at least two locations shows signs of some damage from carpenter bees etc. and need repair and prep and paint.
2.0 Item 1(Picture)
|
||
(3) Some repair areas noticed
2.0 Item 2(Picture)
|
2.1 | Doors (Exterior) | |
Repair or Replace | ||
(1) Weather stripping on a few exterior doors are loose, missing or damaged in areas..
2.1 Item 1(Picture) balcony from kitchen
2.1 Item 2(Picture) garage
|
||
(2) Stain used to protect main doors has faded or failed, and need prep and stain again.
2.1 Item 3(Picture)
|
2.2 | Windows | |
Repair or Replace | ||
Window trim is damaged at the rear of home over the extra room (seen from ground level).
2.2 Item 1(Picture)
|
2.3 | Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings | |
Repair or Replace | ||
(1) The master suite balcony floor is deteriorated. Water has came in along front or outer band where tile or trim failed to cover seam when installed. Tile is cracked in
an area. Guard rail and tile will need to be replaced. Guard rail can be re used but tile likely cannot. Subfloor will need to be replaced along front length of balcony
and side nearest door and install tile and seal.
2.3 Item 1(Picture)
2.3 Item 2(Picture)
2.3 Item 3(Picture)
|
||
(2) Loose stone at steps of home at entry.
2.3 Item 4(Picture)
|
||
(3) Balcony off Living room will need railings cleaned and painted. Some areas of supports for railing appear weathered and light deterioration may exist.
|
||
(4) Decorative railing at parking lot is rusting and needs rust inhibitor, sanding and paint. Also on the roof and due to the slope a boom vehicle may be needed to
access and properly prep and paint.
2.3 Item 5(Picture)
|
2.4 | Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building) | |
Repair or Replace | ||
(1) Driveway does not drain water and an attempt to correct with trench drains is not par with the expectations of this home and does not appear to work. Uneven or sag
in areas. A proper repair is to remove pavement, slope correctly and apply new pavement.
2.4 Item 1(Picture)
2.4 Item 2(Picture)
|
||
(2) Reattaining wall has at least one loose stone and some areas need grout again and sealant applied.
2.4 Item 3(Picture)
|
2.6 | Other | |
Not Inspected | ||
The decorative pond out front is not working. This could be because the pond leaks or is not operable?
2.6 Item 1(Picture)
|
3.1 | Walls (Structural) | |
Repair or Replace | ||
Rock wall has settled or continues to settle and repair signs indicate it has settled previously and has settled more or again. Repairs
are needed to wall and cement chinking. See roof section at Gutters and downspouts for more repair recommendations.
3.1 Item 1(Picture)
|
4.0 | Heating and Cooling Equipment | |
Repair or Replace | ||
Air handler was leaking condensation into the drain pan. The drain pan was full and eventually the safety switch did cut off unit.
However it still leaked which could mean that the pan itself may leak at a seam? Note: The listing agent called a HVAC person who did
replace the filter that was clogged and troubleshooted the system. I did not see if he removed the standing water. Not doing so can
cause more to leak onto the ceiling below. The ceiling below was dripping water and has already stained. I did not inspect for mold and
it could develop. Repairs if air handler was repaired will likely be prime seal ceiling and re paint.
4.0 Item 1(Picture)
4.0 Item 2(Picture)
4.0 Item 3(Picture)
|
4.7 | Gas/LP Firelogs and Fireplaces | |
Repair or Replace | ||
The remote for Formal Living room fireplace was not found and I could not turn on fireplace?
|
5.0 | Plumbing Drain, Waste and Vent Systems | |
Repair or Replace | ||
(1) Both sinks in shared bathroom upstairs drains slow.
5.0 Item 1(Picture)
5.0 Item 2(Picture)
|
||
(2) The diverter on tub spout does not divert all water from tub to shower enough to affect the flow.
|
5.1 | Plumbing Water Supply, Distribution System and Fixtures | |
Repair or Replace | ||
(1) Shower fixture leaked in a few areas where seals may be old. Recommend repair or replace as necessary.
5.1 Item 1(Video)
|
||
(2) Control knobs for guest bath sink upstairs (light blue room) appear to be installed opposite to normal direction to turn water off and on.
Volume or pressure here is somewhat low compared to the other plumbing locations in the home.
5.1 Item 2(Video)
|
||
(3) Protective cover for fixture has sagged or loosened to where water can get in behind wall at light blue guest bedroom upstairs and at
master shower,
5.1 Item 3(Picture)
5.1 Item 4(Picture)
|
5.2 | Hot Water Systems, Controls, Chimneys, Flues and Vents | |
Repair or Replace | ||
Water connection to water heater leaks or has corroded and may have temporarily stopped leaking due to corrosion? A plumber
should repair or replace as needed.
5.2 Item 1(Picture)
|
5.3 | Main Water Shut-off Device (Describe location) | |
Repair or Replace | ||
Main water has leaked or leaking at connection. Drip stains seen on replacement filters for HVAC being stored below. This is a high
pressure area and needs connection fittings replaced. Line could rupture or become worse. A plumber should replace.
5.3 Item 1(Picture)
|
6.3 | Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | |
Repair or Replace | ||
I was unable to see the light fixture work or come on in the upstairs Master? It could be that all bulbs are burned out or it may require
an electrician.
6.3 Item 1(Picture)
|
8.0 | Ceilings | |
Repair or Replace | ||
Tape used to bed Gypsum board seams are loose, failed in a few areas of home including 4 corners of highest ceiling as well as Master bedroom upstairs. Work will
require painting all ceiling to match. Due to the height this will require a means to access the area, and can increase the cost to repair.
8.0 Item 1(Picture)
|
8.1 | Walls | |
Repair or Replace | ||
Baseboard and trim missing from both sides of fireplace in Master bedroom.
8.1 Item 1(Picture)
8.1 Item 2(Picture)
|
8.2 | Floors | |
Repair or Replace | ||
Tile floor in Master needs grout where missing and reseal.
8.2 Item 1(Picture)
8.2 Item 2(Picture)
|
8.6 | Windows (representative number) | |
Repair or Replace | ||
(1) Double window cannot open fully due to the gutter being too low at shared bathroom upstairs.
8.6 Item 1(Picture)
|
||
(2) Window in light blue guest bedroom upstairs is showing odd signs between glass that looks like blisters? It does not appear cloudy. Replace if desired.
|
9.3 | Garage Door (s) | |
Repair or Replace | ||
All three garage doors are no longer protected by the stain or sealant and are starting to peel, fade and eventually deteriorate.
9.3 Item 1(Picture)
9.3 Item 2(Picture)
9.3 Item 3(Picture)
9.3 Item 4(Picture)
|
9.5 | Garage Door Operators (Report whether or not doors will reverse when met with resistance) | |
Repair or Replace | ||
Garage door 1st on left from outside will not close properly and requires holding button in.
|
10.0 | Dishwasher | |
Repair or Replace | ||
It appears that the silverware tray is missing?
10.0 Item 1(Picture)
|
INVOICE |
HomeGauge Software
122 Lyman Street Asheville, NC 28801 828-254-2030 Inspected By: Russell Buchanan |
Inspection Date: 5/17/2017
Report ID: |
Customer Info: | Inspection Property: |
Sample Buyer
Customer's Real Estate Professional: Nath Dau-Schmidt DauSchmidt Realty |
586 Mountain Fancy Drive Big Lake NC 28715 |
| ||||
Tax $0.00 | ||||
Total Price $0.00 |
Payment Method:
Payment Status:
Note: